Brand Name : Uchi

Model Number : OBV5-C40

Certification : CE / SGS / ISO9001

Place of Origin : Dongguan China

MOQ : 200 piece

Price : Negotiate

Payment Terms : T/T, L/C, Western Union

Supply Ability : 60000 pieces per month

Delivery Time : 5-15 days after payment

Packaging Details : export package / Negotiate

Name : Lightning Protector

Color : White

Voltage : 385V/440/420V

Material : MOV/Nylon/PBT

Imax : 40KA

In : 20kA

Time of response : 25ns

Protection rating : IP 20

CertificationCE,CQC : CE / CQC / SGS

Contact Now

IP 20 Protection rating Type 2 Surge Protector With 20KA 40KA

The lightning arrester is connected in parallel to the protected equipment or facility. Normally, the device is insulated from the ground. When a lightning overvoltage occurs, the device and the ground change from insulation to conduction, and break down and discharge, and the lightning current or overvoltage is introduced into the ground. Play a protective role. After the overvoltage is terminated, the lightning arrester quickly restores the blocked state and resumes normal operation. Lightning protectors are mainly used to protect power equipment and power lines, and are also used as safety measures to prevent high voltage from invading indoors. The lightning arrester has a protective gap, a tubular arrester, a valve arrester and a zinc oxide arrester.

OBV5-C40


The surge arrestors OBV5-C40-LT meet the type 2 requirement class according to IEC 61643-11. These devices protect low-voltage consumer systems from overvoltages of all types and are available in single-pole to four-pole versions. The use of high-performance varistors permits a rapid response time and a low protection level, without any line follow current. If circumstances are uncertain and there is a risk of fire from an overload, the internal cut-off unit disconnects the arrestor from the mains if necessary. In addition, the QR code printed on the arrestor allows disary. In addition, the QR code printed on the arrestor allows direct access to the online installation instructions.


Technical Parameters

Model: OBV5-C40
Maximum continuous voltage AC Uc V 275/320/385/440
SPD to EN 61643-11 Type 2
SPD to IEC 61643-1 class II
Nominal discharge current (8/20< s) In kA 20
Maximum discharge current (8/20< s) Imax kA 40
Voltage protection level Up kV < 1,3/1,5/1,8/2,0
Response time tA ns < 25
Maximum back-up fuse A 125
Temperature range ϑ -40℃~+85℃
Protection rating IP 20
Max. cable cross-section flexible (fine-wire) mm² 25
Max. cable cross-section rigid (single wire/multi-wire) mm² 35


Feature&Benefits

1,Protect electric system and on-loading electrical apparatus from thunder and instantaneous over-voltage.
2,Protect transmission of Ethernet signals with 48V DC / 34V AC power supply circuits against
lightning induced surges.
3,Enhanced surge protection.
4,For mounting on 35mm DIN rails acc. to EN 60715.
5,It can effectively ensure the equipments work properly.
·Easy installation or retrofit.
·Din-rail mountable.
·Fail-safe /self-protected designRemote indicator (optional) with 3pin NO/NC contact.
·IP20 finger-safe designVisual indicator.

Application


●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers

Necessity of lightning protection detection:

1.lightning protection detection surge protector can resist lightning disasters and ensure life safety.

The damage of lightning to buildings can only be avoided through lightning protection devices. Lightning directly hits buildings or equipment exposed to the air, and various overhead metal cables will cause equipment damage, and even more serious fires will cause people to bring damage to the equipment. Unnecessary property damage. Professional lightning protection testing companies can do professional lightning protection. The lightning protection testing is to check whether the installed lightning protection devices or structural equipment are reasonable, whether the protection conditions meet the requirements, and whether the electrical safety meets the standards. If it fails to meet the requirements, the lightning protection inspection company will promptly put forward corresponding rectification opinions;

2.Lightning protection device test results meet national standards.

The detection results of lightning protection devices of well-known domestic lightning protection inspection companies are based on the standards of the national professional departments, and the lightning protection inspection companies also use the relevant lightning protection technical standards and standards of the country and various departments as the measurement index. Professional lightning protection testing companies also have relatively more testing content. A series of lightning protection testing software and equipment involved in the detection process can objectively make standard judgments on lightning protection work, so the accuracy of the data results is also higher;

How to choose a suitable power arrester:

   When choosing lightning arresters to protect different types of equipment in an area, the following factors should be considered comprehensively:

●The intensity of thunderstorms in the area, the number of days of thunderstorms and the parameters of the maximum discharge current and the probability of occurrence;

●The value of the protected equipment;

●The level of impact resistance of the protected equipment;

●The social importance of protected equipment;

●Determine the power surge arrester with different protection voltage UP and discharge current;

Others


Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):

Type No. Rated Voltage(V) Un Continuous Voltage Uc(V~) Standard Discharge Current In(KA)

Max Discharge Current
Imax(KA)

Protection Level(KA~) Response Time(ns)
DGM1(2)-D5 220/380

275/320
385/420

5 10 1.2 ≤25
DGM1(2)-D10 10 2 1.6
DGM1(2)-C20 20 40 1.8
DGM13-B30 30 60 .2.2
DGM3(4)-B40 10 80 2.4
DGM(4)-B60 60 100 2.8
DGM-N-PE 220/255 40/60 60/80 1.2 ≤100

Key parameters of power surge protector:

●Maximum continuous withstand voltage Uc (rms):
means that the arrester can work continuously at this voltage value without affecting its parameters as the arrester. Uc is non-linearly proportional to the protection voltage Up.


● Maximum discharge current Imax:
Use 8/20μs wave surge arrester once, the maximum discharge current that can withstand. It can be selected according to the local thunderstorm intensity Ng (or the average annual thunderstorm day Td) and environmental factors.


●Residual voltage Ur and protection voltage Up
Residual voltage Ur: Refers to the residual voltage value under the rated discharge current In.
Protection voltage Up: The protection voltage Up is related to the Uc voltage and Ur. According to the characteristics of the zinc oxide varistor, when the Uc value of the selected varistor is high, its Up and Ur will increase accordingly, such as when the discharge current is 10kA (8/20μs):
Uc=275V Ur (10kA, 8/20μs) ≤1200V
Uc=385V Ur (10kA, 8/20μs) ≤1600V
Uc=440V Ur (10kA, 8/20μs) ≤1800V


Product Tags:

IP20 telephone lightning arrestor

      

SGS type 2 surge arrester

      

IP20 type 2 surge arrester

      
Quality IP20 Type 2 Surge Arrester SGS Approved For Telecommunications for sale

IP20 Type 2 Surge Arrester SGS Approved For Telecommunications Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangdong Uchi Technology Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)